WEKO3
アイテム
{"_buckets": {"deposit": "a150293b-f4db-4479-b60d-aba81e376df7"}, "_deposit": {"created_by": 3, "id": "2178", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "2178"}, "status": "published"}, "_oai": {"id": "oai:rakuno.repo.nii.ac.jp:00002178", "sets": ["29"]}, "author_link": ["5570", "5567", "5568", "5566", "5569"], "item_2_biblio_info_9": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "84", "bibliographicPageStart": "77", "bibliographicVolumeNumber": "14", "bibliographic_titles": [{"bibliographic_title": "Journal of Veterinary Science"}]}]}, "item_2_description_43": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_2_description_6": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Electroretinography (ERG) is a well-established diagnostic procedure for objectively evaluating retinal function. In this study, ERG in beagle dogs, which are a popular experimental animal, was performed to determine the normal range of ERG variables and assess differences between the left and right eyes. ERG findings including rod, combined rod-cone, single-flash cone, and 30-Hz flicker responses were recorded with an LED-electrode in 43 sedated beagle dogs. The subjects were divided into young (\u003c 1 year old), adult (1~5 years old), and senile animals (≥ 6 years old). Normal ERG ranges were obtained. Significant differences in b-wave amplitude along with b/a ratio of the combined rod-cone response were found between the young and adult animals as well as young and senile dogs. No significant differences were observed between the left and right eyes. ERG variables in beagle dogs differed by age due to age-related retinal changes. Thus, we propose that normal ERG ranges should be determined according to age in each clinic and laboratory using its own equipment because each institution usually has different systems or protocols for ERG testing.", "subitem_description_type": "Abstract"}]}, "item_2_publisher_36": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Korean Society of Veterinary Science"}]}, "item_2_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.4142/jvs.2013.14.1.77", "subitem_relation_type_select": "DOI"}}]}, "item_2_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2013 The Korean Society of Veterinary Science. This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License. To view a copy of this license, visit (http://creativecommons.or"}]}, "item_2_source_id_10": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1229-845X", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Itoh, Yoshiki"}], "nameIdentifiers": [{"nameIdentifier": "5566", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Maehara, Seiya"}], "nameIdentifiers": [{"nameIdentifier": "5567", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Itoh, Norihiko"}], "nameIdentifiers": [{"nameIdentifier": "5568", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamashita, Kazuto"}], "nameIdentifiers": [{"nameIdentifier": "5569", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Izumisawa, Yasuharu"}], "nameIdentifiers": [{"nameIdentifier": "5570", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-09-15"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "S-2014-175_maehara.pdf", "filesize": [{"value": "434.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 434900.0, "url": {"label": "S-2014-175_maehara.pdf", "url": "https://rakuno.repo.nii.ac.jp/record/2178/files/S-2014-175_maehara.pdf"}, "version_id": "abd0cc2a-91ae-45fc-a5c2-84c92755639b"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "age group", "subitem_subject_scheme": "Other"}, {"subitem_subject": "beagle dog", "subitem_subject_scheme": "Other"}, {"subitem_subject": "electroretinography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "LED-electrode", "subitem_subject_scheme": "Other"}, {"subitem_subject": "normal range", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Electroretinography recordings using a light emitting diode active corneal electrode in healthy beagle dogs", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Electroretinography recordings using a light emitting diode active corneal electrode in healthy beagle dogs"}]}, "item_type_id": "2", "owner": "3", "path": ["29"], "permalink_uri": "http://hdl.handle.net/10659/3832", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-05-12"}, "publish_date": "2015-05-12", "publish_status": "0", "recid": "2178", "relation": {}, "relation_version_is_last": true, "title": ["Electroretinography recordings using a light emitting diode active corneal electrode in healthy beagle dogs"], "weko_shared_id": -1}
Electroretinography recordings using a light emitting diode active corneal electrode in healthy beagle dogs
http://hdl.handle.net/10659/3832
http://hdl.handle.net/10659/3832288fc088-e5e6-4333-9459-41bbb90f14a4
名前 / ファイル | ライセンス | アクション |
---|---|---|
S-2014-175_maehara.pdf (434.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-05-12 | |||||
タイトル | ||||||
タイトル | Electroretinography recordings using a light emitting diode active corneal electrode in healthy beagle dogs | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | age group | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | beagle dog | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | electroretinography | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | LED-electrode | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | normal range | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Itoh, Yoshiki
× Itoh, Yoshiki× Maehara, Seiya× Itoh, Norihiko× Yamashita, Kazuto× Izumisawa, Yasuharu |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Electroretinography (ERG) is a well-established diagnostic procedure for objectively evaluating retinal function. In this study, ERG in beagle dogs, which are a popular experimental animal, was performed to determine the normal range of ERG variables and assess differences between the left and right eyes. ERG findings including rod, combined rod-cone, single-flash cone, and 30-Hz flicker responses were recorded with an LED-electrode in 43 sedated beagle dogs. The subjects were divided into young (< 1 year old), adult (1~5 years old), and senile animals (≥ 6 years old). Normal ERG ranges were obtained. Significant differences in b-wave amplitude along with b/a ratio of the combined rod-cone response were found between the young and adult animals as well as young and senile dogs. No significant differences were observed between the left and right eyes. ERG variables in beagle dogs differed by age due to age-related retinal changes. Thus, we propose that normal ERG ranges should be determined according to age in each clinic and laboratory using its own equipment because each institution usually has different systems or protocols for ERG testing. | |||||
書誌情報 |
Journal of Veterinary Science 巻 14, 号 1, p. 77-84, 発行日 2013-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1229-845X | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.4142/jvs.2013.14.1.77 | |||||
権利 | ||||||
権利情報 | © 2013 The Korean Society of Veterinary Science. This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License. To view a copy of this license, visit (http://creativecommons.or | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | Korean Society of Veterinary Science | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article |