ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 1:大学
  2. 2.獣医学群
  3. 2.獣医保健看護学類
  4. 学術論文(雑誌)

Performance evaluation of a newly designed on-farm blood testing system for determining blood non-esterified fatty acid and β-hydroxybutyrate concentrations in dairy cows

http://hdl.handle.net/10659/00007009
http://hdl.handle.net/10659/00007009
50d33a68-285a-4775-b1b1-9ccf3da663e3
名前 / ファイル ライセンス アクション
R-2021-74_oikawa.pdf R-2021-74_oikawa.pdf (306.9 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-04-01
タイトル
タイトル Performance evaluation of a newly designed on-farm blood testing system for determining blood non-esterified fatty acid and β-hydroxybutyrate concentrations in dairy cows
言語
言語 eng
キーワード
主題Scheme Other
主題 Dairy cow
キーワード
主題Scheme Other
主題 Non-esterified fatty acids
キーワード
主題Scheme Other
主題 β-Hydroxybutyrate
キーワード
主題Scheme Other
主題 On-farm blood testing
キーワード
言語 en
主題Scheme Other
主題 Dairy cow
キーワード
言語 en
主題Scheme Other
主題 Non-esterified fatty acids
キーワード
言語 en
主題Scheme Other
主題 β-Hydroxybutyrate
キーワード
言語 en
主題Scheme Other
主題 On-farm blood testing
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 FUKUMORI, Rika

× FUKUMORI, Rika

WEKO 19384
教員総覧 9454


ja-Kana 福森, 理加


Search repository
Taguchi, Takayuki

× Taguchi, Takayuki

WEKO 21973

Taguchi, Takayuki

Search repository
Oetzel, Garrett R.

× Oetzel, Garrett R.

WEKO 21974

Oetzel, Garrett R.

Search repository
及川, 伸

× 及川, 伸

WEKO 4644
教員総覧 9406

en OIKAWA, Shin

ja 及川, 伸


Search repository
抄録
内容記述タイプ Abstract
内容記述 The objective of this study was to evaluate a newly designed on-farm blood testing system (OFBTS) for monitoring blood concentrations of non-esterified fatty acids (NEFA) and β-hydroxybutyrate (BHBA) in dairy cows. Blood samples from 230 Holstein dairy cows between −86 and 343 days in milk were collected. A drop of whole blood was used to determine NEFA and BHBA using the OFBTS. Plasma from the remaining blood was used to determine both analytes using a commercial kit (gold standard). In the repeatability of the OFBTS, the intra-assay CV for NEFA and BHBA were 1.3% and 4.5%, and the inter-assay CV were 1.8% and 2.9%, respectively. The slope and coefficient of determination of OFBTS analysis of NEFA compared to the gold standard were 0.92 and 0.94. Those for BHBA were 0.94 and 0.98. Mean of the difference between the gold standard laboratory assays and OFBTS of NEFA and BHBA were 0.021 and 0.019, respectively. However, the bias became substantial for NEFA in the higher concentration ranges (>1.2 mEq/L). The sensitivity and specificity of NEFA were 93.2% and 99.4% at a cutpoint of 0.4 mEq/L, and 87.9% and 100% at 0.6 mEq/L. Those of BHBA were 86.2% and 99.0% at a cutpoint of 1.0 mM, and 94.7% and 99.5% at 1.2 mM. The reaction time for the NEFA to reach 0.6 mEq/L was 7 min. The BHBA reaction reached 1.2 mM within 2 min. In conclusion, the OFBTS has excellent performance for evaluating blood NEFA or BHBA concentrations.
書誌情報 Research in Veterinary Science

巻 135, p. 247-252, 発行日 2021-03
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.rvsc.2020.09.011
権利
権利情報 © 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license.
権利(URI)
権利情報 http://creativecommons.org/licenses/by-nc-nd/4.0/ | http://creativecommons.org/licenses/by-nc-nd/4.0/
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
出版者
出版者 Elsevier Ltd.
資源タイプ
内容記述タイプ Other
内容記述 Article
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 07:35:50.055138
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3