Ion-exclusion/cation-exchange Chromatography with Dual Detection of the Conductivity and Spectrophotometry for the Simultaneous Determination of Common Inorganic Anionic Species and Cations in River and Wastewater

http://hdl.handle.net/10659/3150
http://hdl.handle.net/10659/3150
e73900e5-c19b-4d45-8706-4597d62d5848
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-06-04
タイトル
タイトル Ion-exclusion/cation-exchange Chromatography with Dual Detection of the Conductivity and Spectrophotometry for the Simultaneous Determination of Common Inorganic Anionic Species and Cations in River and Wastewater
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 中谷, 暢丈

× 中谷, 暢丈

WEKO 3613
教員総覧 9380

en NAKATANI, Nobutake

ja 中谷, 暢丈


Search repository
KOZAKI, Daisuke

× KOZAKI, Daisuke

WEKO 3716

KOZAKI, Daisuke

Search repository
MORI, Masanobu

× MORI, Masanobu

WEKO 3717

MORI, Masanobu

Search repository
HASEBE, Kiyoshi

× HASEBE, Kiyoshi

WEKO 3718

HASEBE, Kiyoshi

Search repository
NAKAGOSHI, Nobukazu TANAKA Kazuhiko

× NAKAGOSHI, Nobukazu TANAKA Kazuhiko

WEKO 3719

NAKAGOSHI, Nobukazu TANAKA Kazuhiko

Search repository
TANAKA, Kazuhiko

× TANAKA, Kazuhiko

WEKO 3720

TANAKA, Kazuhiko

Search repository
抄録
内容記述タイプ Abstract
内容記述 Simultaneous determinations of common inorganic anionic species (SO_4^<2−>, Cl^−, NO_3^−, phosphate and silicate) and cations (Na^+, NH_4^+, K^+, Mg^<2+> and Ca2+) were conducted using an ion-chromatography system with dual detection of conductivity and spectrophotometry in tandem. The separation of ionic species on a weakly acidic cation-exchange resin was accomplished using a mixture of 100 mM ascorbic acid and 4 mM 18-crown-6 as an acidic eluent (pH 2.6), after which the ions were detected using a conductivity detector. Subsequently, phosphate and silicate were analyzed based on derivatization with molybdate and spectrophotometry at 700 nm. The detection limits at S/N = 3 ranged from 0.11 to 2.9 μM for analyte ionic species. This method was applied to practical river water and wastewater with acceptable criteria for the anion-cation balance and comparisons of the measured and calculated electrical conductivity, demonstrating the usefulness of the present method for water quality monitoring.
書誌情報 Analytical Sciences

巻 27, 号 5, p. 499-504, 発行日 2011-05
DOI
識別子タイプ DOI
関連識別子 10.2116/analsci.27.499
出版者
出版者 日本分析化学会(Analytical Sciences 編集委員会)
資源タイプ
内容記述タイプ Other
内容記述 Article
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 09:03:57.580037
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3