{"created":"2023-06-19T07:02:59.168191+00:00","id":5192,"links":{},"metadata":{"_buckets":{"deposit":"7b602512-78b2-45c4-aff9-69e41c7362f2"},"_deposit":{"created_by":3,"id":"5192","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"5192"},"status":"published"},"_oai":{"id":"oai:rakuno.repo.nii.ac.jp:00005192","sets":["9:27:28:29"]},"author_link":["16174","16169","16173","16171","16172","16170"],"item_2_biblio_info_9":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"1182","bibliographicPageStart":"1179","bibliographicVolumeNumber":"78","bibliographic_titles":[{"bibliographic_title":"The Journal of veterinary medical science"}]}]},"item_2_description_43":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_description_6":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We investigated the basic characteristics of indirect arterial blood pressure (ABP) measurement using a device that combines oscillometry and photoplethysmography in cats. Dobutamine was infused intravenously in four anesthetized cats. Direct ABP was measured by a catheter. Indirect ABP was measured from the left forelimb. Dobutamine significantly elevated both systolic arterial pressure (SAP) and mean arterial pressure (MAP) in a dose-dependent manner. The indirect SAP, MAP and diastolic arterial pressure (DAP) values were closely correlated with the direct ABP values (r=0.88, 0.89 and 0.83, respectively). The mean bias for SAP, MAP and DAP was 3.4, 0.2 and −2.4 mmHg, respectively. The indirect ABP measured by this device may be used to reliably monitor ABP changes in anesthetized cats.","subitem_description_type":"Abstract"}]},"item_2_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本獣医学会"}]},"item_2_relation_11":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"0916-7250","subitem_relation_type_select":"ISBN"}}]},"item_2_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://dx.doi.org/10.1292/jvms.15-0612","subitem_relation_type_select":"DOI"}}]},"item_2_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"HEISHIMA, Yasuhiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"HORI, Yasutomo"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"CHIKAZAWA, Seishiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KANAI, Kazutaka"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"HOSHI, Fumio"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ITOH, Naoyuki"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-04-12"}],"displaytype":"detail","filename":"R-2017-176_Hori.pdf","filesize":[{"value":"550.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"R-2017-176_Hori.pdf","url":"https://rakuno.repo.nii.ac.jp/record/5192/files/R-2017-176_Hori.pdf"},"version_id":"661b21a5-a02a-4dc5-a5c6-2b8525e6bf08"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"blood pressure","subitem_subject_scheme":"Other"},{"subitem_subject":"feline","subitem_subject_scheme":"Other"},{"subitem_subject":"oscillometry","subitem_subject_scheme":"Other"},{"subitem_subject":"photoplethysmography","subitem_subject_scheme":"Other"},{"subitem_subject":"systemic hypertension","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography"}]},"item_type_id":"2","owner":"3","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-04-12"},"publish_date":"2018-04-12","publish_status":"0","recid":"5192","relation_version_is_last":true,"title":["Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T08:06:18.256125+00:00"}