{"created":"2023-06-19T07:03:24.159764+00:00","id":5690,"links":{},"metadata":{"_buckets":{"deposit":"82633195-10a4-4682-a99a-96f0143a1d31"},"_deposit":{"created_by":3,"id":"5690","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"5690"},"status":"published"},"_oai":{"id":"oai:rakuno.repo.nii.ac.jp:00005690","sets":["9:27:28:29"]},"author_link":["18031","18026","18027","4519","18029","4715","18028","18030","4914"],"item_2_biblio_info_9":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"8","bibliographicPageEnd":"1445","bibliographicPageStart":"1437","bibliographicVolumeNumber":"79","bibliographic_titles":[{"bibliographic_title":"The Journal of veterinary medical science"}]}]},"item_2_description_43":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_description_6":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Changes in stroke volume variation (SVV) and pulse pressure variation (PPV) in response to fluid infusion were experimentally evaluated during vecuronium infusion and sevoflurane anesthesia in 5 adult, mechanically ventilated, euvolemic, beagle dogs. Sequential increases in central venous pressure (CVP; 3–7[baseline], 8–12, 13–17, 18–22 and 23–27 mmHg) were produced by infusing lactated Ringer’s solution and 6% hydroxyethyl starch solution. Heart rate (beats/min), right atrial pressure (RAP, mmHg), pulmonary arterial pressure (PAP, mmHg), pulmonary capillary wedge pressure (PCWP, mmHg), transpulmonary thermodilution cardiac output (TPTDCO, l/min), stroke volume (SV, ml/beat), arterial blood pressure (ABP, mmHg), extravascular lung water (EVLW, ml), pulmonary vascular permeability index (PVPI, calculated), SVV (%), PPV (%) and systemic vascular resistance (SVR, dynes/sec/cm^5) were determined at each predetermined CVP range. Heart rate (P=0.019), RAP (P<0.001), PAP (P<0.001), PCWP (P<0.001), TPTDCO (P=0.009) and SV (P=0.04) increased and SVR (P<0.001), SVV (P<0.001) and PPV (P<0.001) decreased associated with each stepwise increase in CVP. Arterial blood pressure, EVLW, PVPI and the arterial partial pressures of oxygen and carbon dioxide did not change. The changes in SVV and PPV directly reflected the fluid load and the minimum threshold values for detecting fluid responsiveness were SVV ≥11% and PPV ≥7% in dogs.","subitem_description_type":"Abstract"}]},"item_2_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本獣医学会"}]},"item_2_relation_11":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"0916-7250","subitem_relation_type_select":"ISBN"}}]},"item_2_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1292/jvms.16-0287","subitem_relation_type_select":"DOI"}}]},"item_2_rights_16":{"attribute_name":"権利(URI)","attribute_value_mlt":[{"subitem_rights":"https://creativecommons.org/licenses/by-nc-nd/4.0/ | https://creativecommons.org/licenses/by-nc-nd/4.0/"}]},"item_2_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"ENDO, Yusuke"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TAMURA, Jun"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ISHIZUKA, Tomohito"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ITAMI, Takaharu"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"HANAZONO, Kiwamu","creatorNameLang":"en"},{"creatorName":"華園, 究","creatorNameLang":"ja"}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"三好, 健二郎","creatorNameLang":""}],"familyNames":[{"familyNameLang":""}],"givenNames":[{"givenNameLang":""}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"SANO, Tadashi"}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"YAMASHITA, Kazuto","creatorNameLang":"en"},{"creatorName":"山下, 和人","creatorNameLang":"ja"}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"MUIR, William W."}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-08"}],"displaytype":"detail","filename":"R-2018-197_hanazono.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"R-2018-197_hanazono.pdf","url":"https://rakuno.repo.nii.ac.jp/record/5690/files/R-2018-197_hanazono.pdf"},"version_id":"3764dacb-f4e3-4c5c-b543-f78db03a9ec3"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"dog","subitem_subject_scheme":"Other"},{"subitem_subject":"fluid infusion","subitem_subject_scheme":"Other"},{"subitem_subject":"pulse pressure variation","subitem_subject_scheme":"Other"},{"subitem_subject":"stroke volume variation","subitem_subject_scheme":"Other"},{"subitem_subject":"dog","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"fluid infusion","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"pulse pressure variation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"stroke volume variation","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Stroke volume variation (SVV) and pulse pressure variation (PPV) as indicators of fluid responsiveness in sevoflurane anesthetized mechanically ventilated euvolemic dogs","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Stroke volume variation (SVV) and pulse pressure variation (PPV) as indicators of fluid responsiveness in sevoflurane anesthetized mechanically ventilated euvolemic dogs"}]},"item_type_id":"2","owner":"3","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-08-08"},"publish_date":"2019-08-08","publish_status":"0","recid":"5690","relation_version_is_last":true,"title":["Stroke volume variation (SVV) and pulse pressure variation (PPV) as indicators of fluid responsiveness in sevoflurane anesthetized mechanically ventilated euvolemic dogs"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-08-31T02:10:54.675326+00:00"}