{"created":"2023-06-19T07:04:11.664278+00:00","id":6759,"links":{},"metadata":{"_buckets":{"deposit":"9e1a4a85-0d8b-4c4a-b76b-48376f28c26b"},"_deposit":{"created_by":3,"id":"6759","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"6759"},"status":"published"},"_oai":{"id":"oai:rakuno.repo.nii.ac.jp:00006759","sets":["9:10:11:14"]},"author_link":["21899","21898","19412","21897"],"item_2_biblio_info_9":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"198","bibliographicPageStart":"191","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"The Journal of Physical Fitness and Sports Medicine"}]}]},"item_2_description_43":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_2_description_6":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Work-matched high-intensity intermittent cycling training (HIICT) reportedly improves VO_<2max> regardless of the combination of loads and cadences. However, the effect of work-matched HIICT with different combinations of loads and cadences on anaerobic work capacity is unknown. This study aims to investigate the effects of work-matched HIICT with different loads and cadences on Wingate anaerobic test (WAnT) performance, which is an index of anaerobic work capacity. University athletes performed HIICT either with high-load / 60 rpm (HL60, n = 8) or low-load / 120 rpm (LL120, n = 8). HIICT consisted of eight sets of pedaling for 20 s with 10 s of passive rest between each set. Initial exercise intensity was set at 135% of VO_<2peak> and decreased by 5% after every two sets. HIICT was performed for 18 sessions during the 6-week period. Pre and post the training period, peak power, peak rpm, average power, and time to reach peak power during WAnT and VO_<2peak> were measured. According to two-way analysis of variance (time × group), the main effect of time was observed in VO2peak, peak power, peak rpm, and average power during WAnT (p < 0.05). However, time × group interaction was not observed for any indices (p > 0.05). Conversely, time × group interaction was observed in time to reach peak power during WAnT, and significantly shortened only in HL60 (p < 0.05). These results suggest the effectiveness of work-matched HIICT with high-load / low cadence on WAnT performance.","subitem_description_type":"Abstract"}]},"item_2_relation_11":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"2186-8131","subitem_relation_type_select":"ISBN"}}]},"item_2_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.7600/jpfsm.10.191","subitem_relation_type_select":"DOI"}}]},"item_2_rights_16":{"attribute_name":"権利(URI)","attribute_value_mlt":[{"subitem_rights":"https://creativecommons.org/licenses/by-nc-nd/4.0/ | https://creativecommons.org/licenses/by-nc-nd/4.0/"}]},"item_2_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tomabechi, Nobuyasu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takizawa, Kazuki"}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Shibata, Keisuke","creatorNameLang":"en"},{"creatorName":"柴田, 啓介","creatorNameLang":"ja"}],"familyNames":[{},{}],"givenNames":[{},{}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Mizuno, Masao"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-02-21"}],"displaytype":"detail","filename":"R-2021-37_shibata.pdf","filesize":[{"value":"365.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"R-2021-37_shibata.pdf","url":"https://rakuno.repo.nii.ac.jp/record/6759/files/R-2021-37_shibata.pdf"},"version_id":"d21d52e6-6739-4568-86e7-240a640442da"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"VO_<2peak>","subitem_subject_scheme":"Other"},{"subitem_subject":"time to reach peak power","subitem_subject_scheme":"Other"},{"subitem_subject":"peak power","subitem_subject_scheme":"Other"},{"subitem_subject":"average power","subitem_subject_scheme":"Other"},{"subitem_subject":"VO_<2peak>","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"time to reach peak power","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"peak power","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"average power","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Effects of work-matched high-intensity intermittent cycling training with different loads and cadences on Wingate anaerobic test performance in university athletes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Effects of work-matched high-intensity intermittent cycling training with different loads and cadences on Wingate anaerobic test performance in university athletes"}]},"item_type_id":"2","owner":"3","path":["14"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-02-21"},"publish_date":"2022-02-21","publish_status":"0","recid":"6759","relation_version_is_last":true,"title":["Effects of work-matched high-intensity intermittent cycling training with different loads and cadences on Wingate anaerobic test performance in university athletes"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-08-30T02:56:29.163374+00:00"}