WEKO3
アイテム
Utilization of Ion-Exclusion Chromatography for Water Quality Monitoring in a Suburban River in Jakarta, Indonesia
http://hdl.handle.net/10659/4262
http://hdl.handle.net/10659/426209040323-52b7-45e1-8c16-ad8c9c266258
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-05-23 | |||||
タイトル | ||||||
タイトル | Utilization of Ion-Exclusion Chromatography for Water Quality Monitoring in a Suburban River in Jakarta, Indonesia | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ion-exclusion chromatography | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | inorganic ions | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | microbial reaction | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | suburban river | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | water in developing countries | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Kozaki, Daisuke
× Kozaki, Daisuke× Ozaki, Takashi× Nakatani, Nobutake× Mori, Masanobu× Tanaka, Kazuhiko |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We evaluated the use of ion-exclusion chromatographic systems for analyzing the behavior of inorganic ions (e.g., bicarbonate, sulfate, chloride, nitrate, phosphate, dissolved silicate, sodium, ammonium, potassium, magnesium, and calcium ions) in a suburban river located in Jakarta, Indonesia. Carbonate, phosphate, and silicate ion concentrations were determined using ion-exclusion chromatography (IEC) on a weakly acidic cation-exchange resin column (WCX) in the H^+-form with water eluent. Other ions were identified by ion-exclusion/cation-exchange chromatography (IEC/CEC) on a WCX column with tartaric acid eluent. The use of IEC systems for water quality monitoring was advantageous for the following reasons: (1) the concentrations of analyte ions, except NO_3− and silicate ions, increased from upstream to downstream; and (2) the speciation of inorganic nitrogen ions could be analyzed by single injection into the IEC/CEC. The IEC approach provided beneficial information for the construction of sewage treatment facilities in our study area. Results showed that (1) the analyte concentrations for samples obtained in the downstream area were higher than those in the upstream area owing to contamination by domestic sewage; (2) the concentrations of NO_3^− and NH_4^+ correlated with the concentration of dissolved oxygen; and (3) bicarbonate concentrations increased downstream, likely due to respiration of bacteria and dissolution of concrete under low-oxygen conditions. | |||||
書誌情報 |
Water 巻 6, 号 7, p. 1945-1960, 発行日 2014-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2073-4441 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3390/w6071945 | |||||
権利 | ||||||
権利情報 | This is an open access article distributed under the Creative Commons Attribution License (CC BY) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. | |||||
権利(URI) | ||||||
権利情報 | http://creativecommons.org/licenses/by/3.0/ | http://creativecommons.org/licenses/by/3.0/ | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | MDPI AG | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article |