Utilization of Ion-Exclusion Chromatography for Water Quality Monitoring in a Suburban River in Jakarta, Indonesia

http://hdl.handle.net/10659/4262
http://hdl.handle.net/10659/4262
09040323-52b7-45e1-8c16-ad8c9c266258
名前 / ファイル ライセンス アクション
S-2015-25_nakatani.pdf S-2015-25_nakatani.pdf (644.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-05-23
タイトル
タイトル Utilization of Ion-Exclusion Chromatography for Water Quality Monitoring in a Suburban River in Jakarta, Indonesia
言語
言語 eng
キーワード
主題Scheme Other
主題 ion-exclusion chromatography
キーワード
主題Scheme Other
主題 inorganic ions
キーワード
主題Scheme Other
主題 microbial reaction
キーワード
主題Scheme Other
主題 suburban river
キーワード
主題Scheme Other
主題 water in developing countries
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kozaki, Daisuke

× Kozaki, Daisuke

WEKO 3956

Kozaki, Daisuke

Search repository
Ozaki, Takashi

× Ozaki, Takashi

WEKO 3957

Ozaki, Takashi

Search repository
Nakatani, Nobutake

× Nakatani, Nobutake

WEKO 3958

Nakatani, Nobutake

Search repository
Mori, Masanobu

× Mori, Masanobu

WEKO 3959

Mori, Masanobu

Search repository
Tanaka, Kazuhiko

× Tanaka, Kazuhiko

WEKO 3960

Tanaka, Kazuhiko

Search repository
抄録
内容記述タイプ Abstract
内容記述 We evaluated the use of ion-exclusion chromatographic systems for analyzing the behavior of inorganic ions (e.g., bicarbonate, sulfate, chloride, nitrate, phosphate, dissolved silicate, sodium, ammonium, potassium, magnesium, and calcium ions) in a suburban river located in Jakarta, Indonesia. Carbonate, phosphate, and silicate ion concentrations were determined using ion-exclusion chromatography (IEC) on a weakly acidic cation-exchange resin column (WCX) in the H^+-form with water eluent. Other ions were identified by ion-exclusion/cation-exchange chromatography (IEC/CEC) on a WCX column with tartaric acid eluent. The use of IEC systems for water quality monitoring was advantageous for the following reasons: (1) the concentrations of analyte ions, except NO_3− and silicate ions, increased from upstream to downstream; and (2) the speciation of inorganic nitrogen ions could be analyzed by single injection into the IEC/CEC. The IEC approach provided beneficial information for the construction of sewage treatment facilities in our study area. Results showed that (1) the analyte concentrations for samples obtained in the downstream area were higher than those in the upstream area owing to contamination by domestic sewage; (2) the concentrations of NO_3^− and NH_4^+ correlated with the concentration of dissolved oxygen; and (3) bicarbonate concentrations increased downstream, likely due to respiration of bacteria and dissolution of concrete under low-oxygen conditions.
書誌情報 Water

巻 6, 号 7, p. 1945-1960, 発行日 2014-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 2073-4441
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.3390/w6071945
権利
権利情報 This is an open access article distributed under the Creative Commons Attribution License (CC BY) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
権利(URI)
権利情報 http://creativecommons.org/licenses/by/3.0/ | http://creativecommons.org/licenses/by/3.0/
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
出版者
出版者 MDPI AG
資源タイプ
内容記述タイプ Other
内容記述 Article
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 09:03:19.735001
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3