The Simultaneous Determination of Silicic, Boric and Carbonic Acids in Natural Water via Ion-Exclusion Chromatography with a Charged Aerosol Detector
http://hdl.handle.net/10659/00005383
http://hdl.handle.net/10659/00005383e4c29d16-0536-43bf-9dd8-6496fe7e02ad
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-04-12 | |||||
タイトル | ||||||
タイトル | The Simultaneous Determination of Silicic, Boric and Carbonic Acids in Natural Water via Ion-Exclusion Chromatography with a Charged Aerosol Detector | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ion-exclusion chromatography (IEC) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Corona^<TM> charged aerosol detector (C-CAD) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | silicic acid | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | boric acid | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | carbonic acid | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | conversion column | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Otsuka, Yu
× Otsuka, Yu× 中谷, 暢丈× Takahashi, Takuya× Kozaki, Daisuke× Mori, Masanobu× Tanaka, Kazuhiko |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The simple and simultaneous determination of silicic, boric and carbonic acids was made using ion-exclusion chromatography (IEC) and a Corona^<TM> charged aerosol detector (C-CAD). Silicic and boric acids were separated by the column packed with a weakly acidic cation-exchange resin in H+-form and ultra-pure water eluent, and the detector responses were improved by the addition of acetonitrile to eluent. Under the optimized conditions, the simultaneous determination of weak inorganic acids, except for carbonic acid, was successfully performed. When the conversion column packed with a strong acidic cation-exchange resin in Na^+- or K^+-form was inserted between the separation column and the detector, weak inorganic acids including carbonic acid could be detected by the C-CAD. The calibration curves were linear in the range of 0.5-10 mg·L^<−1> as Si for silicic acid (r^2 = 0.996), 10–100 mg·L^<−1> as B for boric acid (r^2 = 0.998) and 1.3-21 mg·L^<−1> as C for carbonic acid (r^2 = 0.993). The detection limits based on three times the standard deviation were 0.03 mg·L^<−1> as Si for silicic acid, 0.40 mg·L^<−1> as B for boric acid and 0.08 mg·L^<−1> as C for carbonic acid. This method was applicable to river, hot spring and drinking water. | |||||
書誌情報 |
Separations 巻 3, 号 1, p. 9-1-9-10, 発行日 2016-03 |
|||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.3390/chromatography3010009 | |||||
権利 | ||||||
権利情報 | © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license | |||||
権利(URI) | ||||||
権利情報 | https://creativecommons.org/licenses/by/4.0/ | https://creativecommons.org/licenses/by/4.0/ | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | MDPI AG | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article |