WEKO3
アイテム
Evaluation of calcium hydrogen carbonate mesoscopic crystals as a disinfectant for influenza A viruses
http://hdl.handle.net/10659/00005914
http://hdl.handle.net/10659/00005914d5e92648-6b42-4117-b515-f88df793e28d
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-08-08 | |||||
タイトル | ||||||
タイトル | Evaluation of calcium hydrogen carbonate mesoscopic crystals as a disinfectant for influenza A viruses | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | antisepsis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | biosecurity | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | calcium hydrogen carbonate | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | influenza virus | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | public health | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | antisepsis | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | biosecurity | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | calcium hydrogen carbonate | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | influenza virus | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | public health | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
NAKASHIMA, Ryuji
× NAKASHIMA, Ryuji× KAWAMOTO, Masaomi× MIYAZAKI, Shigeru× ONISHI, Rumiko× FURUSAKI, Koichi× OSAKI, Maho× KIRISAWA, Rikio× SAKUDO, Akikazu× ONODERA, Takashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this study, the virucidal effect of a novel electrically charged disinfectant CAC-717 was investigated. CAC-717 is produced by applying an electric field to mineral water containing calcium hydrogen carbonate to generate mesoscopic crystals. Virus titration analysis showed a >3 log reduction of influenza A viruses after treatment with CAC-717 for 1 min in room temperature, while infectivity was undetectable after 15 min treatment. Adding bovine serum albumin to CAC-717 solution did not affect the disinfectant effect. Although CAC-717 is an alkaline solution (pH=12.39), upon contact with human tissue, its pH becomes almost physiological (pH 8.84) after accelerated electric discharge, which enables its use against influenza viruses. Therefore, CAC-717 may be used as a preventative measure against influenza A viruses and for biosecurity in the environment. | |||||
書誌情報 |
The Journal of veterinary medical science 巻 79, 号 5, p. 939-942, 発行日 2017-05 |
|||||
ISBN | ||||||
識別子タイプ | ISBN | |||||
関連識別子 | 0916-7250 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1292/jvms.16-0603 | |||||
権利(URI) | ||||||
権利情報 | https://creativecommons.org/licenses/by-nc-nd/4.0/ | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 日本獣医学会 | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article |